Basic Info.
Product Description
Product Description
UV Sterilization Cabinet
It is suitable for sterilizing high temperature resistant appliances, glass sugar porcelain cups, ceramics, production supplies, currency, non-woven fabric, composite paper, cleaning appliances, tableware, towels, clothes, shoes, packaging materials and other products. The use of three-sided high intensity sterilization, the use of ultraviolet and ozone synergistic sterilization, ozone disinfects areas not exposed to UV rays, kill the surface of the virus or bacteria.
Product Parameter
Technical Parameters:
Model | BJPX-SV200 | |
Type | Type 1 with ozone | Type 1 without ozone |
UV Ray Wavelength | 253.7/184.9nm | 253.7nm |
Sterilization Way | 2 sides of UV ray+1 side of ozone | 3 sides of UV ray |
Capacity | 200L | |
Power | 120W | |
UV Lamp Material | Quartz glass | |
Shelves | Standard 2pc, can be optional | |
Internal Size(mm) | 518*523*778 | |
External Size(mm) | 750*663*1200 | |
Packing Size(mm) | 875*788*1265 | |
Gross Weight(kg) | 100 |
Recommended UV Exposure Time
Microorganism Species | Exposure Dose | Exposure Time |
Bacterial Propagules | ≥10000uw.s/cm2 | 10min |
Bacterial Spores | ≥100000uw.s/cm2 | 10min |
Virus | 10000uw.s/cm2≤Exposure Dose ≤100000uw.s/cm2 | 10min |
Fungal Spores | General Exposure Dose ≤100000uw.s/cm2, Special Exposure Dose 600000uw.s/cm2 | 60min |
When the target microorganism is unknown | ≥100000uw.s/cm2 | 10min |
Remarks: The suitable temperature range for ultraviolet disinfection is 20ºC~40ºC. If the temperature is too high or too low, the disinfection effect will be affected, and the disinfection time can be appropriately extended.
Exhibition and Service
Related Products
Delivery and Packing
Contact Eureka