Product Description
Essential details
Name | Bio-Safety Steam Sterilizer |
Brand | AIKSMED |
Model | MDBS Series |
Application | Liquids,Garments, Tools, Porous Apparatus,Rubbers, Aluminum Caps |
Door type | Hinger Door , Vertical Door, Horizontal Door. |
Chamber Volume | 250L,360L,600L,800L,1000L,1200L, 1500L...4000L |
Design Pressure | -0.1/0.3 MPa |
Design Temperature | 144ºC |
Working Pressure | 0.25 MPa |
Sterilization Temperature | 105-136ºC |
Warranty | 1 year |
Origin | China |
Quantity(sets) | 1 - 1 | 2 - 5 | 6 - 10 | >10 |
Lead time (days) | 60 | 65 | 75 | To be negotiated |
MDBS-P3 Series Bio-Safety Steam Sterilizer is designed and manufactured according to the requirements of Level3 Bio-Safety laboratory (BSL-3 Laboratory or P3 Laboratory). It fully meets the GMP requirements. As an ideal sterilization machine in P3 Laboratory, it can fully guarantee the safety of operators and environment. It is mainly used for sterilization of biological products, utensils, sterile garments, medical instruments, medical dressings and other articles requiring extremely high sterilization requirements.
Application
Features:
·Bio-seal measures between sterile and non-sterile areas.
·Condensate collected and re-sterilized in stand-alone inactivation tank before discharge.
·Portable PT-100 temperature sensor (Class A).
·Multiple liquid cooling mode for option.
·Validation port to test thermal distribution.
·Emergency stop button at two sides.
·Alarm information in form of code and full message.
·Air Filter cartridge pore size 0.22µm.
·Drainage cooling system before discharge into sewer.
Model | Volume (M3) | Chamber (W*H*Dmm) | Overall (W*H*Dmm) | Steam (KG) | Water (KG) | CA (L) | Power (KW) | N/W KG | |
Hinged Door | MDBS-P3-0.25D/S | 0.25 | 500×500×1000 | 1280×1910×1340 | 18 | 120 | 50 | 1.2 | 650 |
MDBS-P3-0.36D/S | 0.36 | 600×600×1200 | 1280×1910×1540 | 22 | 150 | 60 | 1.2 | 800 | |
MDBS-P3-0.6D/S | 0.6 | 610×910×1200 | 1280×1910×1540 | 35 | 300 | 100 | 2.6 | 1200 | |
MDBS-P3-0.8D/S | 0.8 | 610×910×1500 | 1280×1910×1790 | 45 | 350 | 100 | 2.6 | 1400 | |
MDBS-P3-1.0D/S | 1.0 | 610×910×1800 | 1280×1910×2100 | 55 | 400 | 100 | 2.6 | 1600 | |
MDBS-P3-1.2D/S | 1.2 | 680×1180×1500 | 1460×2000×1800 | 65 | 500 | 120 | 4.2 | 1700 | |
MDBS-P3-1.5D/S | 1.5 | 680×1180×1900 | 1460×2000×2100 | 80 | 600 | 120 | 4.2 | 1850 | |
MDBS-P3-2.0D/S | 2.0 | 1000×1200×1700 | 1780×2100×2020 | 100 | 800 | 150 | 4.5 | 2400 | |
MDBS-P3-2.5D/S | 2.5 | 1000×1200×2100 | 1780×2100×2420 | 140 | 1000 | 150 | 4.5 | 2700 | |
Vertical Sliding Door | MDBS-P3-0.3D/S-V | 0.3 | 675×675×660 | 1300×1900×1000 | 18 | 120 | 50 | 1.1 | 800 |
MDBS-P3-0.45D/S-V | 0.45 | 675×675×1000 | 1300×1900×1340 | 27 | 150 | 60 | 1.1 | 900 | |
MDBS-P3-0.55D/S-V | 0.57 | 675×675×1250 | 1300×1900×1590 | 35 | 300 | 100 | 1.6 | 1000 | |
MDBS-P3-0.65D/S-V | 0.68 | 675×675×1500 | 1300×1900×1840 | 40 | 350 | 100 | 1.6 | 1200 | |
MDBS-P3-0.75D/S-V | 0.77 | 675×675×1700 | 1300×1900×2040 | 45 | 350 | 100 | 2.5 | 1300 | |
Horizontal Sliding Door | MDBS-P3-1.0D/S-H | 1.0 | 680×1180×1250 | 2200×2000×1750 | 55 | 400 | 100 | 2.6 | 2100 |
MDBS-P3-1.2D/S-H | 1.2 | 680×1180×1500 | 2200×2000×2000 | 65 | 500 | 120 | 4.2 | 2300 | |
MDBS-P3-1.5D/S-H | 1.5 | 680×1180×1900 | 2200×2000×2400 | 80 | 600 | 120 | 4.2 | 2500 |
AIKSMED is an expert manufacturer of diversed sterilizers and autoclaves, ranging from Cassette Autoclaves for dental &
ophthalmology clinics, Laboratory Steam Sterilizers for research organizations, Saturated Steam Sterilizers for garments and
tools, and Superheated Water Cascade Sterilizers for liquid injections in pharmaceutical industries.
1.What is FAT and SAT?
FAT means Factory Acceptance Test, before delivering autoclaves, customer can send his technician or 3rd party personel to test machines in AIKSMED facotry, it usually takes 2~3 days. SAT means Site Acceptance Test, AIKSMED will send 1~2 engineers to user's site for equipment commissioning and staff training, ensuring production able to be carried out successfully.
2. Is it possible for our autoclave and sterilizers idle for years to restart?
3. Regarding ampoule injection, How to choose between steam sterilizer and superheat water autoclave
Firstly these two kinds of autoclave sterilization machines got their own advantages on heating-up speed and cooling, uniform thermal distribution, and etc. But It mainly depends on the loads packing material and size, if glass ampoule, and size is 1ml, 2ml, 5ml, 10ml, we recommend steam sterilization with advantage of fast heating-up and less cost on utility consumption. However, if the container size over 10ml, then superheated water cascade sterilizer is more appropriate to reduce the broken rate after sterilizing, with advantage of regular heating-up, but it costs more on utility consumption and budget. Customer needs to consider based on own situations and long term operation.