STE-T series Class B autoclave T218/T223 [CLASS B]
DESCRIPTION
Safety and Monitoring:
Double safety protection system prevents the cycle from starting if the door is not correctly locked. This system also prevents the door from opening if the pressure inside the chamber is not equal to atmospheric pressure outside the chamber.
ADDITIONAL INFORMATION
CYCLES
STANDARDS
T218/T223 [CLASS B]
T218/T223 are the highest performance autoclaves with innovative technologies design in Europe. It include 18Liter and 23Liters. With quick cycle fastest 15 minutes only , delayed start, automatic water filling, light signature, descale cycle, label printer available.
Overview:
T218/T223 is a new touch series class B table top autoclaves, with innovative technologies design in Europe. It has the highest performance with 18Liter and 23Liters. With quick cycle fastest 15 minutes only , delayed start, automatic water filling, light signature, descale cycle, label printer available.
T218/T223 is a new touch series class B table top autoclaves, with innovative technologies design in Europe. It has the highest performance with 18Liter and 23Liters. With quick cycle fastest 15 minutes only , delayed start, automatic water filling, light signature, descale cycle, label printer available.
Excellent Performance:
Full automatic table top autoclave with pre-set programs.
Full automatic table top autoclave with pre-set programs.
Complies with European standard EN13060.
Full touch screen.
With quick cycle.
In built independent rapid steam generator ensures quick sterilization cycles.
Rapid post sterilization vacuum drying.
Self-initialization when work in different altitude.
The delayed start lets users programme the sterilization cycle so the cycle also be executed outside working hours.
Both manual water filling and Automatic water filling.
Three different light signature.
Descale cycle included.
Be available to connect with Icanlable SPRT to print the barcode label.
Multilanguage menu: Chinese, English, Spanish, German.
Safety and Monitoring:
Double safety protection system prevents the cycle from starting if the door is not correctly locked. This system also prevents the door from opening if the pressure inside the chamber is not equal to atmospheric pressure outside the chamber.
Pressure safety valve prevents over pressure in the chamber and steam generator.
The power is automatically cut if a short circuit or electrical fault occurs.
Able to detect and identify the exact cause of any problem, and to issue a specific error code to the operator.
Water level main switch in the main tank controlling the min and max water level.
Automatic warning for maintenance.
Documentation:
Printer (option): an internal printer is optional for all ICANCLAVE autoclaves.
Printer (option): an internal printer is optional for all ICANCLAVE autoclaves.
Printer port for label printer: it can connected with Icanlabel SPRT to print label.
USB port : it is used for connecting a USB sticker, all sterilization data are automatically written in the USB stick, and can be ready directly in any PC and stored electronically.
Internal Memory: the last 20 cycles can be automatically stored in the autoclave system, which can be printed out at any time.
ADDITIONAL INFORMATION
Order Code | T218 | T223 |
Model Number | STE-18-T | STE-23-T |
Chamber Dimension | Ø250x350 mm | Ø250x450 mm |
Chamber Volume | 18 L | 23 L |
Number of Trays | 4 | 4 |
Material of Trays | Aluminum | Aluminum |
Size of Trays | 192x285 mm | 192x380 mm |
Voltage, Freq. | 220/110V, 50/60Hz | 220/110V, 50/60Hz |
POWER | 1750 w | 1750 w |
Overall Dimension (WxHxD) | 483x450x635 mm | 483x450x635 mm |
Weight | 50 kgs | 53 kgs |
CYCLES
Program | Temp. [ºC] | Pressure [Mpa] | Sterilization time [min.] | Total time T218/T223 |
QUICK S | 134 | 210 | 4 | 11~15min / 15~20min |
STANDARD B | 134 | 210 | 4 | 30~49min / 38~57min |
SOFT B | 121 | 110 | 20 | 38~54min / 46~62min |
PRION B | 134 | 210 | 18 | 37~52min / 45~60min |
B&D TEST | 134 | 210 | 3.5 | 28~35min |
HELIX TEST | 121 | 110 | 30 | 28~35min |
TEXTILE | 134 | 210 | 3.5 | 28~35min |
VACUUM TEST | - | - | - | 20~25min |
DESCALE | - | - | - | Around 40minutes |
STANDARDS
- 93/42/EEC Directive on Medical Devices.
- 97/23/EEC Directive on Pressure Equipment.
- EN 13060 Small Steam Sterilizers.
- EN 61326, EN 61000 Electromagnetic Compatibility.
- EN 61010-1, UL 61010-1Safety requirements.
- EN 61010-2-040, IEC 61010-2-040. Specific requirements for steam sterilizers used for treatment of medical materials.