Basic Info.
Product Description
Essential details
Name | Horizontal pulse vacuum steam sterilizer |
Brand | AIKSMED |
Model | MST Series |
Application | Pharmaceutical, Biological engineering, Laboratory and other fields to sterilize fabrics, instruments, Lumen instruments, Rubber, Liquid |
Door type | Double Doors |
Chamber Volume | 50L,60L,80L,100L,120L, 135L,150L,185L,200L,300L,450L |
Design Pressure | -0.1/0.3 MPa |
Design Temperature | 144ºC |
Working Pressure | 0.23 MPa |
Sterilization Temperature | 105-138ºC |
Warranty | 1 year |
Origin | China |
Quantity(sets) | 1 - 1 | 2 - 5 | 6 - 10 | >10 |
Lead time (days) | 60 | 65 | 75 | To be negotiated |
MST series Horizontal pulse vacuum steam sterilizer uses saturated steam as sterilization medium, through pulsating vacuum way, the saturated steam completely penetrates to the surface of the article, uses high temperature saturated steam under high pressure to kill all microorganisms and their spores, the sterilization effect is reliable, is the most effective physical sterilization method.
Application
Features:
- Adopts microcomputer control technology, touch screen operation, the whole process (pulsating vacuum, heating, sterilization, exhaust steam, vacuum drying) procedures automatically run.
- Touch screen automatically displays operating status, temperature, pressure, time and other parameters and fault alarm information.
- Has 4 sterilization procedures including instruments, dressings, cavity instruments, rubber, liquid and custom, BD test and vacuum test for users to choose.
- Built-in vacuum pump, three times (can be set) pulsating vacuum, vacuum degree up to -0.090mpa can be fully pumped out of dressings and class A cavity instruments.
- Built-in high efficiency steam generator, can quickly produce constant pressure steam, do not pollute sterilized goods.
- Vacuum drying system, fabric dryness less than 1%, instrument dryness less than 0.1%
- 0.22μm bacterial air filter.Ensure that the air breaking the vacuum is sterile air to avoid re-contamination
- Optional configuration of micro printer, real-time sterilization process and fault alarm information.
Model | Volume (L) | Chamber (Φ×L) | Overall (W*H*Dmm) | Weight (Kg) | Gross Weight (Kg) | Packed (W*H*Dmm) | POWER |
MST-50B | 50 | 316×620 | 870×600×520 | 65 | 77 | 970×900×620 | 220V 50Hz 3.6Kw |
MST-60B | 60 | 386×500 | 985×600×1450 | 105 | 125 | 1085×700×1700 | 380V 50Hz 5.7Kw |
MST-80B | 80 | 386×700 | 985×600×1450 | 120 | 152 | 1085×700×1700 | 380V 50Hz 6Kw |
MST-100B | 100 | 386×860 | 1150×600×1450 | 140 | 175 | 1250×700×1700 | 380V 50Hz 6.6Kw |
MST-120B | 120 | 500×620 | 920×770×1550 | 200 | 250 | 1100×870×1800 | 380V 50Hz 9 Kw |
MST-135B | 135 | 500×700 | 1000×770×1550 | 225 | 270 | 1100×870×1800 | 380V 50Hz 9 Kw |
MST-150B | 150 | 500×780 | 1080×770×1550 | 240 | 290 | 1280×870×1800 | 380V 50Hz 12Kw |
MST-185B | 185 | 500×950 | 1250×770×1550 | 255 | 310 | 1350×870×1800 | 380V 50Hz 12Kw |
MST-200B | 200 | 500×1000 | 1320×770×1550 | 265 | 325 | 1420×870×1800 | 380V 50Hz 12Kw |
MST-300B | 300 | 650×950 | 1350×900×1750 | 350 | 430 | 1450×1000×1950 | 380V 50Hz 18Kw |
MST-450B | 450 | 650×1360 | 1750×900×1750 | 450 | 550 | 1850×1000×1950 | 380V 50Hz 24Kw |
AIKSMED is an expert manufacturer of diversed sterilizers and autoclaves, ranging from Cassette Autoclaves for dental &
ophthalmology clinics, Laboratory Steam Sterilizers for research organizations, Saturated Steam Sterilizers for garments and
tools, and Superheated Water Cascade Sterilizers for liquid injections in pharmaceutical industries.
1.What is FAT and SAT?
FAT means Factory Acceptance Test, before delivering autoclaves, customer can send his technician or 3rd party personel to test machines in AIKSMED facotry, it usually takes 2~3 days. SAT means Site Acceptance Test, AIKSMED will send 1~2 engineers to user's site for equipment commissioning and staff training, ensuring production able to be carried out successfully.
2. Is it possible for our autoclave and sterilizers idle for years to restart?
3. Regarding ampoule injection, How to choose between steam sterilizer and superheat water autoclave
Firstly these two kinds of autoclave sterilization machines got their own advantages on heating-up speed and cooling, uniform thermal distribution, and etc. But It mainly depends on the loads packing material and size, if glass ampoule, and size is 1ml, 2ml, 5ml, 10ml, we recommend steam sterilization with advantage of fast heating-up and less cost on utility consumption. However, if the container size over 10ml, then superheated water cascade sterilizer is more appropriate to reduce the broken rate after sterilizing, with advantage of regular heating-up, but it costs more on utility consumption and budget. Customer needs to consider based on own situations and long term operation.