Steam Autoclave Sterilizer for Clinical Bioedical Waste Disposal Equipment with Microwave Treatment

Get reliable Steam Autoclave Sterilizer for Clinical Biomedical Waste Disposal Equipment with Microwave Treatment from our factory. Expert sterilization solution.
Request a Quote

PRODUCTS DETAILS

  • Overview
  • Product Description
  • Working Principles
  • Product Parameters
  • Applications
  • Technical Advantages
  • Company Profile
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
LYHV-10
Treatment
Microwave Autoclave with Shredder
Treatment Capacity
10kg/Hr
Disinfection Effect
6 Log 10
Total Power
8.0 Kw
Voltage
380 V
Weight
850kg
Manpower
One Non Spetial Skilled Operator
Control Type
PLC Control System, Touch Screen Operation Panel
Alarm System
Microwave, Temperature, etc.
Data Storage and Printing
Yes
Maintenance Reminder Function
Automatic Alarm Function for Maintenance or Faults
Application
Any Infectious Healthcare Waste Including Sharps
Disinfection Temperature
Above 135 C Degree
Microwave
2450 (+/-50)MHz
Disinfection Cycle
30minutes
Environmental
None of Smoke, Zero Emissions
Transport Package
Cartons, Wooden Cases, Pallets
Specification
1544mm*1140mm*(1930mm+350mm)
Trademark
LiYing Technology
Origin
China
HS Code
841920
Production Capacity
100PCS/Year

Product Description

 
Hospital laboratory waste On-site horizontal high pressure steam microwave sterilization Device
 

Product Description

The high temperature microwave disinfection equipment for medical waste is a device that uses the dual effects of microwave and high-pressure steam to disinfect medical waste.
Steam Autoclave Sterilizer for Clinical Bioedical Waste Disposal Equipment with Microwave Treatment


 

Working Principles

It uses the thermal effect of microwave to heat the high-pressure disinfection chamber to maintain temperature and prevent steam condensation. It is sterilized by the sensitivity of bacteria to temperature. In addition, microwave has a non-thermal effect, Non thermal effect refers to other microbial killing effects besides thermal effect, which is a unique effect of microwave sterilization. The heating and warming process of the equipment is also a disinfection process. After the disinfection room reaches 135 ºC or above, it is kept for another 5 minutes to complete the disinfection.

Process Flow


Feeding:
Put the bags with medical waste into the material box in the disinfection chamber, and after loading through the PLC control panel, the material box automatically resets and seals with the disinfection chamber, and then closes the outer double doors.

Disinfection:
Start disinfection through PLC control panel operation, and enter the microwave disinfection stage. After the pressure reaches above 0.33MPa and the temperature reaches above 135 degrees Celsius, keep the disinfection for 5 minutes and then complete the disinfection. The system releases pressure and cools down automatically. After reaching the set temperature and no-pressure state, the outer double door can be opened after being prompted, and the disinfection chamber is automatically moved out.

Shredding:
Take out the material box, pour the sterilized waste into the shredding chamber, and close the chamber flap. At this point, the next cycle of medical waste can be put into the material box of the disinfection chamber, and the outer double doors then closed.

Discharging:
The shredding is started through the PLC control panel, the shredded and unrecognizable waste pieces automatically falls into a new non-infected garbage collector to complete the treatment.
At the same time, the microwave disinfection chamber will carry out the next cycle of disinfection of medical waste simultaneously.

 
Steam Autoclave Sterilizer for Clinical Bioedical Waste Disposal Equipment with Microwave Treatment

 

Product Parameters


 
PARAMETER SPECIFICATIONS
Dimensions of the main unit body Diameter: 1544mm*1140mm*1930(+350mm)
Overall weight 850kg
Treatment type Microwave disinfection technology with post- shredding
Type of process Semi-automatic process
Type of control PLC control system, touch screen operation panel
Automatic feeding system None
Sterilization temperature ≥ 135ºC
Pressure ≥ 0.33MPa
Sterilization cycle ≥ 30 minutes
Installed power 8 Kw
Utility Requirements Electricity: 380V, 50Hz, 3Phase
Treatment capacity * 10 kg/hr (±10%)
Manpower requirements No specialized operator / 1 operator
Assembly and start-up 1 day assembly
Exhaust gas treatment system Contain
Disinfection section material 304 stainless steel
Microwave frequency 2450 +/- 50 MHz
Microwave generator power 1.25kW 
Treatment effect 6 log 10
The treatment effect test uses Bacillus subtilis var. niger spore (ATCC 9372) as biological indicator, with killing logarithm value ≥ 6.00.  
A printer integrated with the machine that can trace cycle data, such as hospital name/operator name/cycle time/weight/cycle status.

Customized Special specifications accepted.

 

Applications

 

Applicable To Various Medical&Healtn Service Institutions

Steam Autoclave Sterilizer for Clinical Bioedical Waste Disposal Equipment with Microwave Treatment


Applicable Range
Liying's MDU-type medical waste microwave disinfection equipment is professionally used for the harmless disposal of medical waste, including medical waste that is classified as infectious, traumatic, and pathological waste. It can also be used in epidemics when dealing with sick and dead poultry.
Steam Autoclave Sterilizer for Clinical Bioedical Waste Disposal Equipment with Microwave Treatment
Blood and Blood Products
Dialysis Waste
Animal Tissues, Body Parts, and Carcasses
Human Tissues, Body Parts, and Limbs
Biological and Non-Hazardous Pharmaceutical
Needles, Syringes, and other Sharps
Research Waste,  Laboratory Specimens,  Surgery Waste
Pathology and Histology Samples
Aids and Hepatitis Waste
Isolation Waste
Cultures and Slides
Intravenous Bags, Blood Bags, and Associated Tubing
Animal Bedding
Trace Chemotherapy/anti- neo plastic waste
soft waste (including gauze, bandages, drapes, gowns, and bedding) from patient care, etc. 

Technical Advantages

 
HIGH DISINFECTION EFFECT
High pressure steam and microwave combination disinfection, the disinfection process only takes 5 minutes. High disinfection efficiency and energy saving;
SECURITY
The door of the microwave disinfection equipment adopts a conductive sealing strip sealing structure and is equipped with an interlocking system to prevent microwave leakage;
ECONOMICAL
Using a water cooled microwave generator, the cooling medium is antifreeze, with a long service life;The disinfection bin is made of 304 stainless steel, it is durable.
 
Steam Autoclave Sterilizer for Clinical Bioedical Waste Disposal Equipment with Microwave Treatment
Steam Autoclave Sterilizer for Clinical Bioedical Waste Disposal Equipment with Microwave Treatment
ENVIRONMENTAL
Equipped with an exhaust gas treatment device, including a high-efficiency filter and an activated carbon filter, the high-efficiency filter is used to treat microorganisms contained in the exhaust gas, with a filter particle diameter of 0.2 μ m. It can filter out almost all microorganisms, and activated carbon filters are used for deodorization.
MARKET ACCEPTANCE
Significant advantages of high disinfection effect, simple operation, zero emissions allows the technology being quickly recognized by the market.


Technologies Comparation

Items LiYing Technology Autoclave Autoclave with a shedder Incinerator
(microwave and high pressure process) (hot steam process) (hot steam process) (high-heat process)
Unrecognisable waste YES X YES YES
Volume of waste reduction YES X YES YES
Mass of waste reduction YES X X YES
Installation requirements Low High High High
Complexity of the installation Low Intermediate Intermediate High
Possibility of installation "in situ" YES YES YES X
Technology approval and recognition by countries all over the world High Intermediate High Low
Level of sterelization High Intermediate High High
Odours Low High Intermediate Intermediate
Level of noise Low Intermediate Intermediate High
Treatment of pathological and anatomical waste YES X YES YES
Cost
ROI High Low Low Low
Investment costs Intermediate Low Intermediate High
Operating costs Low High High High
Maintenance costs Low High High High
Labour costs Low High High High
Environment
Impact on the environment No Intermediate Intermediate High
No contaminated rejection (such as water, steam) YES X X X
Security
Risk for workforce/personnel health (no risk of toxic contaminants released into the air or the treated waste) None Intermediate Intermediate High
 

Company Profile

 

About Us
 

Steam Autoclave Sterilizer for Clinical Bioedical Waste Disposal Equipment with Microwave Treatment
The infectious material is temporarily held in a waste container(s) which in turn, are emptied into an pre storage hopper via a charging system which is located at the front of the MDU, The infectious waste is fed to the shredding system by a feed arm where it is shredded. The shredded material is conveyed through a microwave   section and temperature holding section, respectively for disinfection, with  microwave of 2450MHz  (±50MHz),  temperature ≥95ºC , duration over 45minutes.   The disinfected and unrecognizable (sharps) waste is then discharged into large waste containers (or compaction units) by the discharging screw conveyor. From there the material can be transported to a local municipal landfill for disposal or to a refuse recycling plant.

 

Service
  • Design of construction layout drawing
  • Project construction
  • Shipping and transportation
  • Installation and commissioning
  • Medical waste professional training
  • Project recruitment team
  • Assist operation management
Steam Autoclave Sterilizer for Clinical Bioedical Waste Disposal Equipment with Microwave Treatment
 

Certifications

 

Steam Autoclave Sterilizer for Clinical Bioedical Waste Disposal Equipment with Microwave Treatment

ISO 9001
Quality Management System Certivicate


 
ISO14001
Environmental Management System Certivicate


 
ISO45001
Occupataional Health and Safety Management System Certificate


 
CE
Verrification of MD Compliance
Test Standard:
Mechine Directive 2006/42/EC Annex I
EN ISO 12100:2010
EN 60204-1:2006+A1:2009
 
Steam Autoclave Sterilizer for Clinical Bioedical Waste Disposal Equipment with Microwave Treatment
4 invention patents
76 utility model patents
24 software copyright registration certificates



Product INSPECTION REPORTS by

CCIC Central Plains Agricultural Products & Food Testing (Henan) Co., Ltd.
Our workshops
Steam Autoclave Sterilizer for Clinical Bioedical Waste Disposal Equipment with Microwave Treatment

Steam Autoclave Sterilizer for Clinical Bioedical Waste Disposal Equipment with Microwave Treatment
Our teams

Steam Autoclave Sterilizer for Clinical Bioedical Waste Disposal Equipment with Microwave Treatment
Contribution to society

During the pandemic, our equipment and operators support more than a dozen cities.
Steam Autoclave Sterilizer for Clinical Bioedical Waste Disposal Equipment with Microwave Treatment
Shipping
Steam Autoclave Sterilizer for Clinical Bioedical Waste Disposal Equipment with Microwave TreatmentCustomer's Projects

Steam Autoclave Sterilizer for Clinical Bioedical Waste Disposal Equipment with Microwave Treatment

Steam Autoclave Sterilizer for Clinical Bioedical Waste Disposal Equipment with Microwave Treatment

 

FAQ

 

Q1. Are you a factory or trading company?
We are a professional manufacturing factory since the year 2014. Welcome to visit our factory located in Minquan county, Henan province, China.

Q2. How can I visit your factory?

Visit us on site. You are always warmly welcome to visit our factory on site, just feel free to contact us for an invitation letter.
Visit our factory through online video. Or please never hesitate to contact us, our sales staff will contact you and take you to visit our manufacturing workshop and work site through online video. 

Q3. Where is your factory? How can I get to your factory?
Our factory is located in Minquan county, Henan province, the nearest airport is Zhengzhou Xinzheng International Airport (CGO), and then two hours by car or train to our factory. Or you can also fly to Beijing or Shanghai air port, then get to your county by a high speed train.

Q4. How long about the delivery time for the medical waste disinfection equipment?
 About 20 days to 60days for standard models, feel free to contact us for details.

Q5. Where will the disinfected medical waste go?
The medical waste after microwave disinfection treatment is non-infectious, non-hazardous and unrecognizable inert waste, which can be transported to the local domestic garbage landfill or incineration plant as ordinary domestic garbage for treatment, or part of the medical waste after disinfection treatment can be recycled accordingly. It should be properly handled according to your local laws and regulations.

Q6. I want to build a centralized treatment institute in our city, what could you help me?
Please feel free to contact us NOW, our experienced teams will give you sufficient suggestions on your projects, from marketing research, project scales choose, site selection, land layout, and including economic benefit analysis, operational model, etc. With our 19 centralized treatment centers experience in China, surely we'll help during the whole procedure. 



Other Products

Steam Autoclave Sterilizer for Clinical Bioedical Waste Disposal Equipment with Microwave Treatment
Steam Autoclave Sterilizer for Clinical Bioedical Waste Disposal Equipment with Microwave Treatment
Steam Autoclave Sterilizer for Clinical Bioedical Waste Disposal Equipment with Microwave Treatment
Medical Waste Centralized Treatment Equipment

     Used for centralized treatment of medical waste in fixed place
Mobile Medical Waste Disinfection Vehicle

Used for treatment of medical waste in remote areas, or emergencies.
Medical Waste Transfer Vehicle

Used for medical waste tranported from hospitals or clinics to an centralized treatment center.

Will you have an customized inquiry, please never hesitate to Contact us Now! We'll give efficient suggestions with quotation. 
 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours